Online ups power system
1. Digital Design
Adopted DSP control technology and digital design topology, C UPS can be operated and maintained more conveniently.
2. Reversed Polarity N and L wire Detection Function.
Reversed Polarity of wiring or input protective grounding-wire is abnormal, at this point the indicators will alarm blink cyclically.
3. A Real Green-environmental Protection Power.
The commercial power input factor correction technique is used .Under the Normal mode, UPS achieves real energy-saving by inputting harmonic less than 10% and frequency power factor above 99%.
4. Direct Current Cold Start Function
When battery input voltage in the range of normal voltage. By pressing the ON button ,UPS can start up normally.
5. Alarm High-low Battery Input Voltage Protection Function
UPS alarms in case of the battery input voltage too high or too low. As the battery continuously go up or down out of the normal range, UPS will alarm and stop input or transfer to bypass mode to ensure the battery life and protect user equipment
6. Communication and Monitoring Function
Equipped with standard RS232 interface and intelligent slot. The UPS Operating and electrical parameters can be monitored through standard RS232. Through intelligent slot status interface the intelligent control can be flexibly configured according to different applications to users, for instance ,stem node, network
monitoring, text message
7. Output High- Low Voltage Protection
When UPS output is greater than the output over-voltage protection point or less than the output low-voltage protection point, it will shut off inverter output to bypass and automatically alarm .After all the fault removed, users can restart the machine normally.
8. Output Short Circuit Protection
When the Inverter output overloaded and short circuit ,UPS will stop output and alarm and blink continuously. After the troubleshooting, it can restart normally.
9. Overloaded Protection Function
When Overload out of ranged load in certain time ,UPS will turn off the inverter and switch to Bypass output by alarming .After the load back to normal, UPS automatically transfer back to inverter output.
10. Over-temperature Protection
11. Intelligent Fan Speed Control Function
According to load capability and environmental temperature
Spec of 6-20KVA UPS
model | C6K | C6KS | C10K | C10KS | 3C10KS | 3C15KS | 3C20KS | |
Power rating | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | ||||
Rated voltage | 220±20%Vac | 380±20%Vac | ||||||
Rated Freq | 50Hz | |||||||
Bat Input | Bat Volt | 192VDC | ||||||
Backup time | >4min | with(1) | >3min | (1)depend on external battery bank | ||||
Ac output | Out Volt | 220/230/240Vac±3%inverter output | ||||||
Out Freq | 46-54Hzzline normal,50Hz±1%line abnormal | |||||||
Wave | pure sine wave THD <2%full linear load | |||||||
Power Factor | 0.8 | |||||||
Overload | 105-125% 1min to bypass | |||||||
Communication and monitor | RS232,Intelligent SlotSNMP,Dry contactor and so on | |||||||
Protection function | AC input or output above or below the range of voltage Overload ,overtemperature and short circuit protection | |||||||
Working Envirement | Temper | 10~ +40 | ||||||
humidity | 0~95%,no condensation | |||||||
Altitude | ≤1500m,satisfy GB3859.2-93 | |||||||
Dimension(W*D*H)mm | 248*500*620 | 248*500*460 | 248*500*620 | 248*500*460 | 248*500*620 | |||
Weight(Kg) | 57kg | 18kg | 67.5 kg | 20 kg | 27 | 35 | 35 |